The Elevator Drive

Dedicated elevator drives that are easy to set-up and optimise while providing class-leading ride comfort

E300 Elevator AC Drives

Specialist Drives 

2.2 kW – 250 kW (3 - 400 hp) 
200 V | 400 V | 575 V | 690 V

Dedicated Drives For Class-Leading Ride Comfort

Control Techniques is a leading supplier of variable speed drive technology to the elevator industry, with over 3 million elevators in operation with our control equipment worldwide. Backed by our global network of Drive Centres we provide local expertise and support, along with quick delivery of robust and dependable products.

Our elevator drive solutions work for any size of building. Whether it’s a small residential building or a luxury high rise, new build or modernization projects, we make every step of the process as easy as possible from product selection to installation, setup and service.

Introducing the dedicated Elevator Drive

 

Adding value at every stage of your project 


Freedom to design
  • Broad power range, compact form factor
  • Match any control interface, any protocol
  • Work with any motor, any feedback device
  • Multiple mounting options
  • Dynamic braking and regen solutions
  • Back-up power and rescue modes
 
Effortless installation and commissioning
  • Elevator specific menu structure
  • Stationary autotune
  • Pluggable drive terminals
  • Robust cable management
  • Parameter storage, cloning and security
  • Keypad with backlit LCD display
  • Virtual terminal for access through the lift controller
  • PC tools for set-up and tuning
 
Class-leading performance
  • Creep-to-floor and Direct-to-floor operation
  • Selectable start, run, stop gains
  • Load cell compensation and start locking
  • Start optimiser to overcome stiction
  • Fast start mode
  • Floor sensor correction
  • Short floor landing operation 
 
Maintenance and diagnostics support
  • Selectable status display parameters
  • Diagnostics with timestamping
  • Built-in data logger
  • Normal Terminal Stopping Device support
  • Low voltage rescue mode
  • Blocked elevator car release
  • Travel counter to help keep track the lifetime of plastic ropes

  • Features
    Rapid set-up and adjustment
    • Simple and intuitive parameter adjustment via a bright back-lit LCD keypad
    • Set-up in familiar elevator language and units
    • Easy to use menu structure for quick and simple access to key adjustments
    • Top level menu; all your frequently needed functions in one location
    • Stationary autotune provides encoder phasing test without the need to de-rope the system or to open the motor brakes

     

    Optimum ride comfort
    • Direct-to-floor positioning
    • Peak curve operation
    • High resolution multi-step S-ramp for start, run, slowdown and stopping
    • Ultra-fast current loop for vibration free motor control
    • Advanced brake control management, no rollback on starting without the need of load sensor 

     

    Silent operation
    • EN81-20 / EN81-50 TÜV certified STO enable input removes the need for both output motor contactors
    • High switching frequencies selectable up to 16 kHz
    • Variable speed cooling fan

     

    Energy efficient
    • Standby sleep/wake mode, powers down unused circuitry during prolonged periods of standby
    • Easy connection to a range of regenerative modules

     

    Flexible integration
    • Modbus RTU communications
    • Parallel I/O interface
    • +/- 10V analog reference control
    • Direct RS485 comms control
    • DCP3 and DCP4 communication support with optional System Integration module
    • CANopen communication support with optional System Integration module
    • Tile mount for low profile shaft mounting
    • 24 Vdc backup
    • Simple UPS connection with load direction signal
    • Dynamic braking transistor fitted to all drives as standard

     

    Robust
    • Active thermal management for tripless operation under extreme conditions
    • Advanced power circuit design using latest IGBT technology
    • Conformal coating for use in harsh environments
    • Phase loss detection on both input and output

     

    Enhanced elevator data logger
    • User configurable, for example speed reference, speed feedback, current and I/O sequence can all be recorded for every car journey
    • Can be stored in the event of system fault
    • Available for offline viewing to aid system diagnostics
  • Specifications

    Standard features

    Onboard comms:
    • RS485 communications port MODBUS RTU with integrated command word and built in watchdog

    Safety:
    • 1 x Safe Torque Off (STO) terminal
    • SIL3/PLe compliant

    Keypad:
    • Dedicated elevator keypad supplied as standard, providing:
      • Intuitive elevator application menu structure
      • Easy click-in keypad connection
      • Easy-to-use menu and parameter structure
      • Local and remote mounting
      • Real-time clock
    Option slots:
    • 3
    Parameter cloning via:
    • PC tools
    • Smartcard
    • SD card

     

    200 - 240 Vac, 50-60 Hz ± 10 % Drive Ratings
    PART NUMBER CURRENT (A)
    Peak Current Nominal Current
    03200106A10 21.2 10.6
    04200137A10
    27.4
    13.7
    04200185A10 37 18.5
    05200250A10 50 25
    06200330A10 66 33
    06200440A10 88 44
    07200610A10 122 61
    07200750A10 150 75
    07200830A10 166 83
    08201160A10 232 116
    08201320A10 264 132
    09201760A10 352 176
    09202190A10 438 219
    10202830A 566 283
    10203000A 600 300
     
    For all above
    Switching frequency KHz (selectable 3 to 16 kHz @ 50 % ED)
    Braking transistor built in as standard

     

    380 - 480 Vac, 50-60 Hz ± 10 % Drive Ratings
    PART NUMBER CURRENT (A)
      Peak Current Nominal Current
    03400062A10 11 6.2
    03400078A10
    14
    7.8
    03400100A10 18 10
    04400150A10 27 15
    04400172A10 31 17.2
    05400220A10 39 22
    05400270A10 48 27
    05400300A10 53 30
    06400350A10 62 35
    06400420A10 74 42
    06400470A10 83 47
    07400660A10 116 66
    07400770A10 135 77
    07401000A10 175 100
    08401340A10 235 134
    08401570A10 275 157
    09402000A10 350 200
    09402240A10 385 220
    10402700E 473 270
    10403200E 543 310
     
    For all above
    Switching frequency 8 KHz (selectable 3 to 16 kHz @ 50 % ED)
    Braking transistor built in as standard
     
    500 – 575 Vac, 50-60 Hz ± 10 % Drive Ratings
    PART NUMBER CURRENT (A)
      Peak Current Nominal Current
    05500030A10 5.5 3
    05500040A10
    7
    4
    05500069A10 12
    6.9
    06500100A10
    17.5
    10
    06500150A10
    26.5
    15
    06500190A10
    33.5
    19
    06500230A10
    40.5
    23
    06500290A10
    51
    29
    06500350A10
    54.5
    31
    07500440A10
    77
    44
    07500550A10
    96.5
    55
    08500630A10
    110.5
    63
    08500860A10 150.5
    86
    09501040A10 182
    104
    09501310A10 229.5
    131
    10501520E10 266
    152
    10501900E10 332.5
    190
     
    For all above
    Switching frequency KHz (selectable 3 to 16 kHz @ 50 % ED)
    Braking transistor built in as standard

     

    690 Vac, 50-60 Hz ± 10 % Drive Ratings
    PART NUMBER CURRENT (A)
    Peak Current Nominal Current
    07600190A10 33.5 19
    07600240A10 42 24
    07600290A10
    51 29
    07600380A10
    66.5 38
    07600440A10
    77 44
    07600540A10
    84 48
    08600630A10
    110.5 63
    08600860A10
    150.5 86
    09601040A10
    182 104
    09601310A10
    229.5 131
    10601500E10
    262.5 150
    10601780E10
    311.5 178
     
    For all above
    Switching frequency KHz (selectable 3 to 16 kHz @ 50 % ED)
    Braking transistor built in as standard

     

    Further information from your supplier is available on the following features:

    • UPS operation - all drives have a dedicated rescue mode allowing operation from 200 V UPS

    • DC supply - all drives have the possibility of being supplied from a DC source from 24 V to the maximum voltage rating of the product

    • 500 V, 525 V, 575 V and 690 V units are also available 

  • Options
    Keypads
     
    Remote Keypad RTC
    Remote mountable keypad, allowing flexible mounting on the outside of a panel (meets IP54/NEMA 12). The keypad offers a four line plain text, multi-language LCD display for rapid set-up and helpful diagnostics. A battery operated real-time clock allows accurate time stamping of events, aiding diagnostics.
     

    System Integration Modules - Communications

     

    SI-CANopen
    CANopen interface module supporting various profiles, including several drive profiles

     

    SI-DCP
    DCP interface module                                                                                                                

    System Integration Modules - Feedback

     

    SI-Encoder
    Quadrature encoder input interface module

     

    SI-Universal Encoder
    Encoder input and output interface supporting Quadrature, SinCos, EnDat and SSI encoders

     System Integration Modules - Applications

    SI-Applications Plus
    SI-Applications Plus modules allow SyPTPro application programs to be recompiled and executed to enable rapid and simple upgrade for existing elevator drive users
    MCi200
    Second processor, providing advanced customization using industry standard IEC61131-3 programming languages
    MCi210
    Extended advanced machine control, provides MCi200 functionality with additional ports and simultaneous connectivity to 2 separate Ethernet networks

     System Integration Modules - Additional I/O

     
    SI-I/O
    Extended I/O interface module to increase the number of I/O points on a drive. Provides additional: 4 x Digital I/O, 3 x Analog inputs (default)/Digital inputs, 1 x Analog output (default)/Digital input, 2 x Relays

     Drive interface units - Back-up

     Smartcard
    Smartcard
    Smartcard memory device to back-up and copy parameter sets and basic programs
     
    SD Card Adaptor
    Allows an SD card to be inserted into the Smartcard slot, for parameter backup cloning and application programs

      Drive interface units - Communications

     

    KI-485 Adaptor
    This allows the drive to communicate via RS485. This is commonly used for programming if the drive has no keypad

    CT USB Comms cable
    The USB Comms cable allows the drive to connect to a PC for use with PC tools
  • Software & Support
    We make it quick and easy
    Connect - Intuitive Commissioning Software

    Connect is our latest drive configuration tool for commissioning, optimising and monitoring drive/system performance.

     

    Download

    Diagnostics Tool

    Diagnostic Tool is a fast and simple tool, which allows users of Control Techniques' drives to quickly solve any error codes that the drive may show.

     

    Download

  • Downloads

Further Information

This website uses cookies to ensure you get the best experience on our website. Learn More