3 - 400 hp (2.2 kW – 250 kW)
230 V | 460 V | 575 V | 690 V
Our elevator drive solutions work for any size of building. Whether it’s a small residential building or a luxury high rise, new build or modernization projects, we make every step of the process as easy as possible from product selection to installation, setup and service.
Freedom to design
|
|
Effortless installation and commissioning
|
|
Class-leading performance
|
|
Maintenance and diagnostics support
|
Onboard comms
RS485 communications port MODBUS RTU with integrated command word and built in watchdog
Safety
1 x Safe Torque Off (STO) terminal
SIL3/PLe compliant
Keypad
Option slots
Parameter cloning via
cUL |
USA and Canada (cUL Listed). UL File number: E171230 |
CE |
European Union (all applicable directives and regulations LVD, EMD, RoHS, REACH, Energy related products) |
UKCA |
United Kingdom (all applicable regulations) |
RCM |
Australia and New Zealand (Responsible Supplier Registration No. E6934) |
EAC |
Russian Customs Union. E300 models |
Functional Safety |
Safe Torque Off function. TÜV Rheinland Type Examination Certificates: 01/205/5270.02/17 (Unidrive-M and derivative products) 01/205/5409.02/21 (SI-Safety option module) 01/205/5720.00/19 (MiS210, MiS250 option modules) The safety function "Safe Torque Off" can be used in applications up to Cat 4. PL e according to EN ISO 13849-1, SIL 3 according to EN 61800-5-2/ EN 62061/ IEC 61508, and in lift applications according to EN 81-1 and EN81-2. |
UL Functional Safety |
Unidrive-M all products |
Functional Safety for Elevators | TÜV Nord certificates
44 799 17002401 (Brake contact monitoring feature, E300 series drives) |
ISO |
Quality system: ISO 9001 (Certificate Nos. FM 739405) |
China RoHS |
Chinese Order No. 32, 2016; Administrative Measures for the Restriction of Hazardous Substances in Electrical and Electronic Equipment (China RoHS 2), |
EPA TSCA regulations |
All Commander and Unidrive-M products |
IHM, Basel convention, |
MEPC 68/21 / Add.1, Annex 17, Resolution MEPC.269(68) 2015 Guidelines for the development of the inventory of hazardous materials. |
Responsible Minerals Initiative (RMI) |
CMRT compliance |
PART NUMBER | CURRENT (A) | |
---|---|---|
PEAK CURRENT | NOMINAL CURRENT | |
03400062A10 | 11 | 6.2 |
03400078A10 |
14
|
7.8 |
03400100A10 | 18 | 10 |
04400150A10 | 27 | 15 |
04400172A10 | 31 | 17.2 |
05400220A10 | 39 | 22 |
05400270A10 | 48 | 27 |
05400300A10 | 53 | 30 |
06400350A10 | 62 | 35 |
06400420A10 | 74 | 42 |
06400470A10 | 83 | 47 |
07400660A10 | 116 | 66 |
07400770A10 | 135 | 77 |
07401000A10 | 175 | 100 |
08401340A10 | 235 | 134 |
08401570A10 | 275 | 157 |
09402000A10 | 350 | 200 |
09402240A10 | 385 | 220 |
10402700E | 473 | 270 |
10403200E | 543 | 310 |
Switching frequency 8 KHz (selectable 3 to 16 kHz @ 50 % ED)
Braking transistor built in as standard
PART NUMBER | CURRENT (A) | |
---|---|---|
PEAK CURRENT | NOMINAL CURRENT | |
03200106A10 | 21.2 | 10.6 |
04200137A10 |
27.4 |
13.7 |
04200185A10 | 37 | 18.5 |
05200250A10 | 50 | 25 |
06200330A10 | 66 | 33 |
06200440A10 | 88 | 44 |
07200610A10 | 122 | 61 |
07200750A10 | 150 | 75 |
07200830A10 | 166 | 83 |
08201160A10 | 232 | 116 |
08201320A10 | 264 | 132 |
09201760A10 | 352 | 176 |
09202190A10 | 438 | 219 |
10202830A | 566 | 283 |
10203000A | 600 | 300 |
For all above
Switching frequency 8 KHz (selectable 3 to 16 kHz @ 50 % ED)
Braking transistor built in as standard
Further information from your supplier is available on the following features:
• UPS operation - all drives have a dedicated rescue mode allowing operation from 200 V UPS
• DC supply - all drives have the possibility of being supplied from a DC source from 24 V to the maximum voltage rating of the product
• 500 V, 525 V, 575 V and 690 V units are also available
Remote keypad RTCRemote mountable keypad, allowing flexible mounting on the outside of a panel (meets IP54/NEMA 12). The keypad offers a four line plain text, multi-language LCD display for rapid set-up and helpful diagnostics. A battery operated real-time clock allows accurate time stamping of events, aiding diagnostics. |
|
SI-DCPDCP interface module |
SI-CANopenCANopen interface module supporting various profiles, including several drive profiles |
SI-Universal EncoderEncoder input and output interface supporting Quadrature, SinCos, EnDat and SSI encoders. |
|
SI-EncoderQuadrature encoder input interface module |
SI-ApplicationsSecond processor module, which allows SyPTPro application programs to be re-compiled for Unidrive M700. |
|
MCi200Second processor, providing advanced machine control using Machine Control Studio. |
|
MCi210Adds to the MCi200 with a dual port Ethernet interface directly on the processor and additional I/O |
SI-I/OExtended I/O interface module to increase the number of I/O points on a drive. Provides additional: 4 x Digital I/O, 3 x Analog inputs (default)/Digital inputs, 1 x Analog output (default)/Digital input, 2 x Relays |
SmartcardSmartcard memory device to backup and copy parameter sets and basic PLC programs. |
|
|
SD Card AdaptorAllows an SD card to be inserted into the Smartcard slot, for parameter backup cloning and application programs. |
KI-485 AdaptorThis allows the drive to communicate via RS485. This is commonly used for programming if the drive has no keypad |
|
CT USB Comms cableThe USB Comms cable allows the drive to connect to a PC for use with Unidrive M's PC tools. |
Elevator Connect PC Tool - CommissioningThe Connect PC Tool configures, optimizes and monitors drive/system control and performance |