0.33 hp – 200 hp (0.25 kW – 132 kW) Simplex Pump
0.5 hp – 200 hp (0.37 kW – 132 kW) Multiplex Pump
115 V | 208 - 240 V | 380 - 480 V | 575 V | 690 V
The Control Techniques Unidrive M400 Pumping Solutions are a cost effective and versatile variable speed control system for maintaining energy efficient, constant water pressure in single-phase (0.33 - 50 hp) or 3-phase (0.5 - 200 hp) applications. These single-pump and multi-pump (up to 3 max) configurations utilize the onboard controller on the Unidrive M400 variable frequency AC drive (VFD) for economical and easy to use control.
Based on the highly reliable Unidrive M400 AC drive, these solutions provide programming dedicated to simplex and multiplex pump operation. The AI-CTASP (Simplex Pump) and AI-CTAMP (Multiplex Pump) options include an AI-BACKUP-ADAPTOR with SD memory card pre-loaded with default pump parameters to make application setup easy.
Additionally, an optional HMI (human machine interface) is available that makes setup and diagnostics easy and provides additional features such as remote web access and email alerts.
The Control Techniques’ Unidrive M400 Multiplex Pump solution is an effective and versatile variable speed control system for maintaining constant pressure in a multiple pump configuration for ratings up to 200 hp.
Based on the highly reliable Unidrive M400 AC drive, this solution offers cost effective pump control for up to 3 pumps and includes SI-ETHERNET for inter-drive, EtherNet/IP and Modbus TCP communications. An embedded controller in the drive eliminates the need for an external controller saving cost, space and programming time.
1. Order any frame size 2 or above Unidrive M400. This includes the pre-programmed Unidrive M400 with multiplex pump software and SI-ETHERNET, for example:
Standard Drive: M400-02400013A10101AB100 (with DB transistor) M400-09402000E10101AN100 (without DB transistor)
Multiplex Pump Drive: M400-02400013A10101K0034 (with DB transistor) M400-09402000E10101K0036 (without DB transistor)
2. Order CI-KEYPAD-LCD for access to drive parameters, status and diagnostics and to load SD card pump files from the AI-BACKUP-ADAPTOR. One keypad is recommended to be order at a minimum.
3. Order AI-CTAMP for pump configuration drive parameters for drives one, two and three. This includes an AI-BACKUP-ADAPTOR and SD card with default pump configuration drive parameters pre-loaded. Only one AI-CTAMP is needed to load drive parameters for a multiplex system.
The Control Techniques’ Unidrive M400 Simplex Pump solution is an effective and versatile variable speed control system for maintaining constant pressure in a single pump configuration for ratings up to 200 hp. Based on the highly reliable Unidrive M400 AC drive, this product offers cost effective pump control. An embedded controller in the drive eliminates the need for an external controller saving cost, space and programming time.
Standard Drive: M400-02400013A10101AB100 (with DB transistor) M400-09402000E10101AN100 (without DB transistor)
Multiplex Pump Drive: M400-02400013A10101K0033 (with DB transistor) M400-09402000E10101K0035 (without DB transistor)
SI option modules for Unidrive M400 Simplex Pump Solution (only 1 SI option module permitted per drive frame 2 and above)
SI-I/OExtended I/O interface module to increase the number of I/O points on a drive. Provides additional: 4 x Digital I/O, 3 x Analog inputs (default) / digital inputs, 1 x Digital input, 2 x Relays |
An SI-I/O option module can be ordered with Unidrive M400 simplex pump drives frames 2 and above. This module provides control over additional pump application parameters.
Additional features include:
A variety of SI communications modules can be ordered to add further flexibility to your simplex pump application. The Unidrive M400 Multiplex Pumping solution includes an SI-ETHERNET module as standard. No other SI option modules can be used with the Multiplex Pump solution.
SI-PROFIBUSPROFIBUS DP interface module; Simplex Pump only. |
|
SI-DEVICENETDeviceNet interface module; Simplex Pump only. |
|
SI-CANOPENCANopen interface module supporting various profiles, including several drive profiles; Simplex Pump only. |
|
SI-ETHERNETEthernet module that supports EtherNet/IP and Modbus TCP/IP; standard for Multiplex Pump solution, optional for Simplex Pump solution. |
|
SI-PROFINET-V2PROFINET RT interface module; Simplex Pump only. |
|
SI-ETHERCATEtherCAT interface module; Simplex Pump only. |
Unidrive M400 AC drives do not include a keypad as standard. A CI-KEYPAD is recommended to be ordered for easy setup, diagnostics, and to load SD card files from the AI-BACKUP-ADAPTOR.
CI-Keypad LCDThree line plain text, multi-language LCD keypad for rapid setup and helpful diagnostics maximizes machine up-time. |
||
Remote keypadAll the features of the CI-Keypad LCD, but remote mountable. This allows flexible mounting on the outside of a panel and meets IP66 (NEMA 4) |
||
REMOTE-KEYPAD-RTCThe keypad is remote mountable, allowing flexible mounting on the outside of a panel (meets IP54/ NEMA 12). Three line multi-language plus custom text LCD keypad for rapid setup and helpful diagnostics. Battery operated real-time clock allows accurate time stamping of events, aiding diagnostics. |
A pre-loaded default pump parameter SD card and adaptor can be ordered for backup pump parameters.
AI-485-ADAPTORAdaptor that allows the drive to communicate via Modbus RTU over RS485. |
|
AI-485-24V-ADAPTORAdaptor that allows the drive to communicate via Modbus RTU over RS485, and an input for 24 V backup. |
|
CI-485-ADAPTORAdaptor that allows the drive to communicate via Modbus RTU over RS485, not compatible with CI-KEYPAD-LCD option. |
|
CT-USB-CABLEThe USB Communications cable allows the drive to connect to a PC for use with Unidrive M's PC tools via a Modbus RTU adaptor. |
CTVUE-306A-CTAMPHMI (human machine interface) operator interface provides a graphical interface and adds additional features including auto/hand, flow monitoring, system trip log, email alerts, and remote access for Multiplex Pump systems. |
|
CTVUE-304KE-CTASPHMI (human machine interface) operator interface provides a graphical interface and adds additional features including email alerts, remote web access, system trip log, and flow monitoring for Simplex Pump systems. |