ACPM 900
- Overview
- Downloads
- Duty Table(s)
Imperial Electric's Frame 900 ACPM Gearless Machines boast speeds up to 1,400 feet per minute for up to 8,000 lbs (car capacity, 1:1 roped applications) and 700 feet per minute for up to 9,000 lbs (car capacity, 2:1 roped applications). This machine is great in the following applications: modernization and new construction, 1:1 or 2:1 roped installations, high rise or heavy load, and overhead, basement or side pull applications.
-
MODEL 908 OB-E
- 4,500 lbs capacity Up to 1,400 fpm 1:1 Roping
- 9,000 lbs capacity Up to 700 fpm 2:1 Roping
- Double wrap
- 30.0” drive sheave
- Rope Groove hardness: 245-285 Brinell
- Up to Qty 9-5/8 or 7-3/4” ropes Double Wrap
- Round U Groove
- D:d ratio 48:1 with 5/8” ropes
- D:d ratio 40:1 with 3/4” ropes
- Sheave shaft Load: 120,000 lbs
- Quad Independent disk brake system holds 125% rated capacity-2 each
- Overhead, Basement & Side pull Application
- Extra mounting restraints are needed for Basement & Side pull Application
- M/C Weight: 14,200 lbs
- M/C Torque:
- Rated Torque 908 OB 4853 ft-lb, Accel Torque: 12132 ft-lb
-
Model 908 OB-H
- 8,000 lbs capacity Up to 2,000 fpm 1:1 Roping
- 10,000 lbs capacity Up to 1,000 fpm 1:1 Roping (Special Applications)
- 16,000 lbs capacity Up to 1,000 fpm 2:1 Roping
- Double wrap
- 30.0” drive sheave
- Rope Groove hardness: 245-285 Brinell
- Up to Qty 9-5/8 or 7-3/4” ropes Double Wrap
- Round U Groove
- D:d ratio 48:1 with 5/8” ropes
- D:d ratio 40:1 with 3/4” ropes
- Sheave shaft Load: 120,000 lbs
- Two Independent Hydraulic disk brake system holds 125% rated capacity - 2 each
- Overhead, Basement & Side pull Application
- Extra mounting restraints are needed for Basement & Side pull Application
- M/C Weight: 15,200 lbs
- M/C Torque:
- Rated Torque 908 OB – 6490 ft-lb, Accel Torque: 16225 ft-lb
Brochures
Press Releases
News Articles
Case Studies
Survey Form - PDF
Survey Form - Word
Quote Form - PDF
Quote Form - Word
Product Catalogs
Product Data Sheets
Training
Manuals
Product Page
Quote Form
Survey Form
Notice
Frame 908-OB E Series 1:1 Duty Table
FPM | 500 | 700 | 800 |
1000 |
1200 | 1400 | 1600 | 1800 | 2000 | |||||||||
Freq. (Hz) | 17 | 23.8 | 27.2 | 34 | 40.7 | 47.5 | 542.3 | 61.1 | 67.9 | |||||||||
RPM | 63.7 | 89.1 | 102 | 127.3 | 152.8 | 178.3 | 203.7 | 229.2 | 254.6 | |||||||||
Capacity | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps |
2000 | 16.8 | 37 | 23.6 | 37 | 26.9 | 37 | 33.7 | 44 | 40.4 | 53 | 47.1 | 64 | 53.9 | 67 | 60.6 | 83 | 67.3 | 83 |
2500 | 21 | 46 | 29.5 | 46 | 33.7 | 46 | 42.1 | 55 | 50.5 | 66 | 58.9 | 80 | 67.3 | 84 | 75.8 | 104 | 84.2 | 104 |
3000 | 25.3 | 56 | 35.4 | 56 | 40.4 | 56 | 50.5 | 67 | 60.6 | 79 | 70.7 | 97 | 80.8 | 101 | 90.9 | 124 | 101.0 | 124 |
3500 | 29.5 | 65 | 41.2 | 65 | 47.1 | 65 | 58.9 | 78 | 70.7 | 93 | 82.5 | 113 | 94.3 | 118 | 106.1 | 145 | 117.8 | 145 |
4000 | 33.7 | 74 | 47.1 | 74 | 53.9 | 74 | 67.3 | 89 | 80.8 | 106 | 94.3 | 129 | 107.7 | 134 | 121.2 | 166 | 134.7 | 166 |
4500 | 37.9 | 84 | 53 | 84 | 60.6 | 84 | 75.8 | 100 | 90.9 | 119 | 106.1 | 145 | 121.2 | 151 | 136.4 | 187 | 151.5 | 187 |
Model 908-OB E | All specifications at 50% Counterweight. Consult Imperial Electric for 40% and 45% counterweighting data. |
Frame 908-OB H Series 1:1 Duty Table
FPM | 500 | 700 | 800 | 1000 | 1200 | 1400 | 1600 | 1800 | 2000 | |||||||||
Freq. (Hz) | 17 | 23.8 | 27.2 | 34 | 40.7 | 47.5 | 542.3 | 61.1 | 67.9 | |||||||||
RPM | 63.7 | 89.1 | 102 | 127.3 | 152.8 | 178.3 | 203.7 | 229.2 | 254.6 | |||||||||
Cap. | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps |
5000 | 42.1 | 93 | 58.9 | 93 | 67.3 | 93 | 84.2 | 111 | 101.0 | 132 | 117.8 | 161 | 134.7 | 168 | 151.5 | 207 | 168.4 | 207 |
5500 | 46.3 | 102 | 64.8 | 102 | 74.1 | 102 | 92.6 | 122 | 111.1 | 146 | 129.6 | 177 | 48.1 | 185 | 166.7 | 228 | 185.2 | 228 |
6000 | 50.5 | 112 | 70.7 | 112 | 80.8 | 112 | 101.0 | 133 | 121.2 | 159 | 141.4 | 193 | 161.6 | 202 | 181.8 | 249 | 202.0 | 249 |
6500 | 54.7 | 121 | 76.6 | 121 | 87.5 | 121 | 109.4 | 144 | 131.3 | 172 | 153.2 | 209 | 175.1 | 218 | 197.0 | 270 | 219.9 | 270 |
7000 | 58.9 | 130 | 82.5 | 130 | 94.3 | 130 | 117.8 | 155 | 141.4 | 185 | 165.0 | 225 | 188.6 | 235 | 212.1 | 290 | 235.7 | 290 |
7500 | 63.1 | 139 | 88.4 | 139 | 101.0 | 139 | 126.3 | 166 | 151.5 | 198 | 176.8 | 241 | 202.0 | 252 | 227.3 | 311 | 252.5 | 311 |
8000 | 67.3 | 149 | 94.3 | 149 | 107.7 | 149 | 134.7 | 177 | 161.6 | 212 | 188.6 | 257 | 215.5 | 269 | 242.4 | 332 | 269.4 | 332 |
Model 908-OB H | All specifications at 50% Counterweight. Consult Imperial Electric for 40% and 45% counterweighting data. |
Frame 908-OB E Series 2:1 Duty Table
FPM | 350 | 400 | 450 |
500 |
700 | 800 | 1000 | |||||||
Freq. (Hz) | 23.8 | 27.2 | 30.6 | 34 | 47.5 | 54.3 | 67.9 | |||||||
RPM | 89.1 | 102 | 114.6 | 127.3 | 178.3 | 203.7 | 254.6 | |||||||
Capacity | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps |
3000 | 18.7 | 30 | 21.4 | 30 | 24.1 | 35 | 26.7 | 35 | 37.4 | 51 | 52.8 | 53 | 53.5 | 66 |
4000 | 25.0 | 39 | 28.5 | 39 | 32.1 | 47 | 35.7 | 47 | 49.9 | 68 | 57.0 | 71 | 71.3 | 88 |
5000 | 31.2 | 49 | 35.7 | 49 | 40.1 | 59 | 44.6 | 59 | 62.4 | 84 | 71.3 | 89 | 89.1 | 110 |
6000 | 37.4 | 59 | 42.8 | 59 | 48.1 | 70 | 53.5 | 70 | 74.9 | 102 | 85.6 | 107 | 107.0 | 132 |
7000 | 43.7 | 69 | 49.9 | 69 | 56.1 | 82 | 62.4 | 82 | 873 | 119 | 99.8 | 125 | 124.8 | 154 |
8000 | 49.9 | 79 | 57 | 79 | 64.2 | 94 | 71.3 | 94 | 99.8 | 136 | 114.1 | 142 | 142.6 | 176 |
9000 | 56.1 | 89 | 64.2 | 89 | 72.2 | 106 | 80.2 | 106 | 112.3 | 153 | 128.3 | 160 | 160.4 | 198 |
Model 908-OB E | All specifications at 50% Counterweight. Consult Imperial Electric for40% and 45% counterweighting data. |
Frame 908-OB H Series 2:1 Duty Table
FPM | 350 | 400 | 450 |
500 |
700 | 800 | 1000 | |||||||
Freq. (Hz) | 23.8 | 27.2 | 30.6 | 34 | 47.5 | 54.3 | 67.9 | |||||||
RPM | 89.1 | 102 | 114.6 | 127.3 | 178.3 | 203.7 | 254.6 | |||||||
Capacity | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps |
10000 | 62.4 | 98 | 71.3 | 98 | 80.2 | 117 | 89.1 | 117 | 124.8 | 170 | 142.6 | 178 | 178.3 | 220 |
11000 | 68.6 | 108 | 74.4 | 108 | 88.2 | 129 | 98.0 | 129 | 137.3 | 187 | 156.9 | 196 | 196.1 | 242 |
12000 | 74.9 | 118 | 85.6 | 118 | 96.3 | 141 | 107.0 | 141 | 149.7 | 204 | 171.1 | 214 | 219.9 | 264 |
14000 | 87.3 | 138 | 99.8 | 138 | 112.3 | 164 | 124.8 | 164 | 174.7 | 239 | 119.6 | 249 | 249.6 | 307 |
15000 | 93.6 | 148 | 107.0 | 148 | 120.3 | 176 | 113.7 | 176 | 187.2 | 256 | 213.9 | 267 | 267.4 | 329 |
16000 | 99.8 | 158 | 114.1 | 158 | 128.3 | 188 | 142.6 | 188 | 199.6 | 273 | 228.2 | 285 | 285.2 | 351 |
Model 908-OB E | All specifications at 50% Counterweight. Consult Imperial Electric for40% and 45% counterweighting data. |