3 - 400 hp (2.2 kW – 250 kW)
230 V | 460 V | 575 V | 690 V
Backed by our global network of Drive Centers we provide local expertise and support, along with quick delivery of robust and dependable products.
Our elevator drive solutions work for any size of building. Whether it’s a small residential building or a luxury high rise, new build or modernization projects, we make every step of the process as easy as possible from product selection to installation, setup and service.
Freedom to design
|
|
|
Effortless installation and commissioning
|
|
Class-leading performance
|
|
Maintenance and diagnostics support
|
Onboard comms
RS485 communications port MODBUS RTU with integrated command word and built in watchdog
Safety
1 x Safe Torque Off (STO) terminal
SIL3/PLe compliant
Keypad
Option slots
Parameter cloning via
cUL |
USA and Canada (cUL Listed). UL File number: E171230 |
CE |
European Union (all applicable directives and regulations LVD, EMD, RoHS, REACH, Energy related products) |
UKCA |
United Kingdom (all applicable regulations) |
RCM |
Australia and New Zealand (Responsible Supplier Registration No. E6934) |
EAC |
Russian Customs Union. E300 models |
Functional Safety |
Safe Torque Off function. TÜV Rheinland Type Examination Certificates: 01/205/5270.02/17 (Unidrive-M and derivative products) 01/205/5409.02/21 (SI-Safety option module) 01/205/5720.00/19 (MiS210, MiS250 option modules) The safety function "Safe Torque Off" can be used in applications up to Cat 4. PL e according to EN ISO 13849-1, SIL 3 according to EN 61800-5-2/ EN 62061/ IEC 61508, and in lift applications according to EN 81-1 and EN81-2. |
UL Functional Safety |
Unidrive-M all products |
Functional Safety for Elevators | TÜV Nord certificates
44 799 17002401 (Brake contact monitoring feature, E300 series drives) |
ISO |
Quality system: ISO 9001 (Certificate Nos. FM 739405) |
China RoHS |
Chinese Order No. 32, 2016; Administrative Measures for the Restriction of Hazardous Substances in Electrical and Electronic Equipment (China RoHS 2), |
EPA TSCA regulations |
All Commander and Unidrive-M products |
IHM, Basel convention, |
MEPC 68/21 / Add.1, Annex 17, Resolution MEPC.269(68) 2015 Guidelines for the development of the inventory of hazardous materials. |
Responsible Minerals Initiative (RMI) |
CMRT compliance |
PART NUMBER | CURRENT (A) | |
---|---|---|
PEAK CURRENT | NOMINAL CURRENT | |
03400062A10 | 11 | 6.2 |
03400078A10 |
14
|
7.8 |
03400100A10 | 18 | 10 |
04400150A10 | 27 | 15 |
04400172A10 | 31 | 17.2 |
05400220A10 | 39 | 22 |
05400270A10 | 48 | 27 |
05400300A10 | 53 | 30 |
06400350A10 | 62 | 35 |
06400420A10 | 74 | 42 |
06400470A10 | 83 | 47 |
07400660A10 | 116 | 66 |
07400770A10 | 135 | 77 |
07401000A10 | 175 | 100 |
08401340A10 | 235 | 134 |
08401570A10 | 275 | 157 |
09402000A10 | 350 | 200 |
09402240A10 | 385 | 220 |
10402700E | 473 | 270 |
10403200E | 543 | 310 |
Switching frequency 8 KHz (selectable 3 to 16 kHz @ 50 % ED)
Braking transistor built in as standard
PART NUMBER | CURRENT (A) | |
---|---|---|
PEAK CURRENT | NOMINAL CURRENT | |
03200106A10 | 21.2 | 10.6 |
04200137A10 |
27.4 |
13.7 |
04200185A10 | 37 | 18.5 |
05200250A10 | 50 | 25 |
06200330A10 | 66 | 33 |
06200440A10 | 88 | 44 |
07200610A10 | 122 | 61 |
07200750A10 | 150 | 75 |
07200830A10 | 166 | 83 |
08201160A10 | 232 | 116 |
08201320A10 | 264 | 132 |
09201760A10 | 352 | 176 |
09202190A10 | 438 | 219 |
10202830A | 566 | 283 |
10203000A | 600 | 300 |
For all above
Switching frequency 8 KHz (selectable 3 to 16 kHz @ 50 % ED)
Braking transistor built in as standard
Further information from your supplier is available on the following features:
• UPS operation - all drives have a dedicated rescue mode allowing operation from 200 V UPS
• DC supply - all drives have the possibility of being supplied from a DC source from 24 V to the maximum voltage rating of the product
• 500 V, 525 V, 575 V and 690 V units are also available
Remote keypad RTCRemote mountable keypad, allowing flexible mounting on the outside of a panel (meets IP54/NEMA 12). The keypad offers a four line plain text, multi-language LCD display for rapid set-up and helpful diagnostics. A battery operated real-time clock allows accurate time stamping of events, aiding diagnostics. |
|
SI-DCPDCP interface module |
SI-CANopenCANopen interface module supporting various profiles, including several drive profiles |
|
SI-Universal EncoderEncoder input and output interface supporting Quadrature, SinCos, EnDat and SSI encoders. |
SI-EncoderQuadrature encoder input interface module |
|
SI-ApplicationsSecond processor module, which allows SyPTPro application programs to be re-compiled for Unidrive M700. |
|
MCi200Second processor, providing advanced machine control using Machine Control Studio. |
|
MCi210Adds to the MCi200 with a dual port Ethernet interface directly on the processor and additional I/O |
|
SI-I/OExtended I/O interface module to increase the number of I/O points on a drive. Provides additional: 4 x Digital I/O, 3 x Analog inputs (default)/Digital inputs, 1 x Analog output (default)/Digital input, 2 x Relays |
|
SmartcardSmartcard memory device to backup and copy parameter sets and basic PLC programs. |
|
SD Card AdaptorAllows an SD card to be inserted into the Smartcard slot, for parameter backup cloning and application programs. |
|
KI-485 AdaptorThis allows the drive to communicate via RS485. This is commonly used for programming if the drive has no keypad |
CT USB Comms cableThe USB Comms cable allows the drive to connect to a PC for use with Unidrive M's PC tools. |
Elevator Connect PC Tool - CommissioningThe Connect PC Tool configures, optimizes and monitors drive/system control and performance |